If a device is not first browsed in RSLinx Classic software, the IntelliCENTER software cannot communicate to that device and IntelliCENTER software shows the device to be in communication loss. The Driver Configuration dialog box varies depending on which driver you select. Use the 20-750-DNET option card to communicate with the PowerFlex 753/755 drives over the DeviceNet network. The 20-COMM-D option card is not a supported option for the PowerFlex 753/755 drives. IntelliCENTER software version 5.00.01 and later does not communicate with PowerFlex 753/755 drives via the 20-COMM-D option card. Clear the Always Run as Service checkbox, and click Start. From the Start Menu, choose Programs > Rockwell Software > RSLinx > RSLinx Classic Launch Control Panel. If RSLinx Classic software does not start, then start the application from the RSLinx Classic Launch Control Panel.

rslinx classic lite 3.61 rslinx classic lite 3.61

If the devices do not appear in the RSWho, then IntelliCENTER software is not able to monitor the device. This is because certain EDS files require a restart of the computer before RSLinx Classic software is able to identify the device in the RSWho. If IntelliCENTER software data disks or EDS files were recently installed, then restart the computer before browsing the associated network in RSLinx Classic software. If you have multiple networks, browse each network that IntelliCENTER software monitors. Allow all nodes on a network to be browsed.Ĩ. Select the driver and browse to the appropriate networks that IntelliCENTER software is communicating with.ħ. From the Communications pull-down menu, choose RSWho.Ħ. Complete the information in the Driver Configuration dialog box that is displayed.Īfter successfully adding the new driver, the network must be browsed.ĥ. From the Available Driver Types pull-down menu, choose the most appropriate driver for your communication platform.Ĥ. In RSLinx Classic software, from the Communications menu, choose Configure Drivers.ģ. From the Start menu, choose Programs > Rockwell Software > RSLinx > RSLinx Classic.Ģ. RSLinx Classic software is the communication platform between the IntelliCENTER hardware and software.įollow these steps to configure the RSLinx software drivers needed on your computer.ġ.

rslinx classic lite 3.61

During the installation of the IntelliCENTER software program disk, RSLinx® Classic Lite software was installed (unless RSLinx software was installed on the personal computer prior to installation of the IntelliCENTER software).













Rslinx classic lite 3.61